Description
Jbl Proflora Co2 Ph Sensor Set — BNC pH electrode and calibration kit for CO2 controllers
An automatic CO2 system is only as accurate as the pH reading driving it, and a drifting electrode either starves plants of CO2 or quietly overdoses the tank while the display still looks normal. Jbl Proflora Co2 Ph Sensor Set (SKU: 112901) is JBL’s replacement pH electrode and calibration kit for its ProFlora CO2 Control unit and other pH measuring or dosing devices fitted with a BNC connector, with each unit individually tested and shipped with its own test report. The set supplies the sensor itself plus everything needed to calibrate, clean and maintain it, rather than the bare electrode alone.
Included in the set: a 2 m cable fixed to the electrode for routing from the controller to the tank, 2 suction cups to hold the electrode in the aquarium, 3 cuvettes, and 50 mL each of storage solution, distilled water and calibration liquid at pH 7.0 and pH 4.0. JBL recommends recalibrating the electrode every 30 to 45 days, using a temperature sensor at the same time since pH readings shift with temperature; on a healthy electrode the reading should stay within about 0.02 to 0.05 pH of the calibration standard, and the voltage difference measured between the pH 7.0 and pH 4.0 solutions should sit above roughly 140 to 150 mV. If the controller shows an instability warning, JBL’s advice is to clean the sensor head and leave it soaking in the storage solution for 24 hours before calibrating again; an electrode that still will not settle is due for replacement, typically needed every two years of use.
Usage & Application
When to Use
- New CO2 controller: First electrode for a JBL ProFlora CO2 Control or similar BNC pH device.
- Scheduled replacement: Swapping out an electrode at around the two-year mark.
- Drifting readings: Replacing a sensor that will not settle after cleaning and recalibration.
- Routine calibration: Restocking calibration and storage solution for the 30 to 45-day check.
Installation & Setup Guide
- Mount in a dark spot: Fix the electrode with the suction cups away from bright light, since light encourages algae on the tip.
- Connect via BNC: Plug the cable into the controller or dosing device.
- Calibrate before use: Soak in the pH 7.0 then pH 4.0 solution, confirming the reading against each before leaving it in the tank.
- Store the cap filled: Keep the protective cap topped up with storage solution whenever the electrode is out of the water.
Product Specifications & Highlights
Key Features
- BNC connector: Fits the JBL ProFlora CO2 Control and other BNC pH devices.
- Individually tested: Each electrode ships with its own test report.
- Full calibration kit: Includes pH 7.0 and pH 4.0 calibration liquid, storage solution and distilled water.
- 2 m cable: Reaches from a typically mounted controller to the tank.
- 30 to 45-day calibration cycle: JBL’s stated interval for accurate readings.
Product Details
- Brand: JBL (Germany)
- SKU: 112901
- Barcode (GTIN/EAN): 4014162646514
- Product Type: Aquascaping & CO2 > CO2/pH Electrode & Calibration Set
- Contents: BNC pH electrode, 2 m cable, 2 suction holders, 3 cuvettes, 50 mL storage solution, 50 mL distilled water, 50 mL calibration liquid pH 7.0, 50 mL calibration liquid pH 4.0
- Connector: BNC
- Compatible With: JBL ProFlora CO2 Control and other BNC-connector pH devices
- Calibration Interval: Every 30–45 days
- Electrode Life: About 2 years with regular care
- Target Environment: Freshwater planted aquariums